1707 - Slot X Drive Array Controller - Bootstrap NVRAM checksum failed

1708 - Slot X Drive Array Controller - Bootstrap NVRAM restored from backup. System restart required

1711-Slot z Drive Array - RAID ADG Logical Drive(s) Configured but Array Accelerator Size <= 32 MB...

1711-Slot z Drive Array - Stripe size too large for RAID 5/6 logical drive(s).

1712-Slot X Drive Array - RAID 5 logical drive(s) configured with 56 Drives, but Array Accelerator size <= 32 MB...

1713-Slot Z Drive Array Controller - Redundant ROM Reprogramming Failure...

1714-Slot Z Drive Array Controller - Redundant ROM Checksum Error...

1715-Slot X Drive Array Controller - Memory Error(s) Occurred

1716-Slot z Drive Array Controller - Unrecoverable Media Errors Detected on Drives

1717-Slot z Drive Array Controller - Disk Drive(s) Reporting OVERHEATED Condition

1718-Slot z Drive Array Controller - Device discovery found more devices attached to this controller than firmware currently supports...

1719-Slot z Drive Array - A controller failure event occurred prior to this power-up (previous lock-up code = 0x####)

1720-Slot X Drive Array - S.M.A.R.T. Hard Drive(s) Detect Imminent Failure SCSI: Port Y: SCSI ID Z.

1720-S.M.A.R.T. Hard Drive Detects Imminent Failure

1721-Slot X Drive Array - Drive Parameter Tracking Predicts Imminent Failure...

1724-Slot X Drive Array - Physical Drive Position Change(s) Detected - ...

1725-Slot X Drive Array-Optional SIMM Failure Detected

1726-Slot X Drive Array - Array Accelerator Memory Size Change Detected. - ...

1727-Slot X Drive Array - New Logical Drive(s) Attachment Detected...

1729-Slot 1 Drive Array - Performance Optimization Scan In Progress...

1732-Slot z Drive Array - Array Accelerator Battery Pack Missing...

1733-Slot z Drive Array - Storage Enclosure Firmware Upgrade Problem Detected...

1735-Slot z Drive Array - Unsupported Redundant Cabling Configuration Detected...

1736-HP Trusted Platform Module Error

1737-Slot z Drive Array - Redundant Cabling Configuration has excess Device Paths...

1738-Slot z Drive Array - Storage Enclosure Redundant Cabling Problem Detected

1739-Slot z Drive Array - Redundant Cabling Configuration is not as recommended...

1742-Slot z Drive Array - Previously Ejected Drive(s) Detected...

1743-Slot z Drive Array - Logical Drive Erase Operation in Progress...

1744-Slot z Drive Array - Drive Erase Operation Running or Queued...

1745-Slot z Drive Array - Drive Erase Operation Completed...

1746-Slot z Drive Array - Unsupported Storage Connection Detected...

1747-Slot z Drive Array - Unsupported Array Configuration Detected...

1748-Slot X Drive Array - Unsupported Array Accelerator Battery Attached...

1753-Slot Z Drive Array - Array Controller Maximum Operating Temperature Exceeded During Previous Power Up

1754-Slot X Drive Array - RAID ADG configured but ADG is not supported on this controller model.

1754-Slot z Drive Array - One or more RAID levels are configured...

1757-Slot z Array Accelerator module Incompatible with this controller...

1762-Slot X Drive Array - Controller Firmware Upgrade Needed

1763-Array Accelerator Daughtercard is Detached; Please Reattach

1764-Slot X Drive Array - Capacity Expansion Process is Temporarily Disabled...

1768-Slot X Drive Array - Resuming Logical Drive Expansion Process

1769-Slot X Drive Array - Drive(s) Disabled Due to Failure During Capacity Expansion

1770-Slot X Drive Array - SCSI Drive Firmware Update Recommended - ...

1774-Slot X Drive Array - Obsolete Data Found in Array Accelerator

1775-Slot X Drive Array - ProLiant Storage System Not Responding SCSI Port Y:

1775-Slot X Drive Array - ProLiant Storage System Not Responding SCSI Port Y:

1776-Slot X Drive Array - SCSI Bus Termination Error

1776-Slot X Drive Array - Shared SAS Port Connection Conflict Detected - Ports 1I, 1E: Storage connections detected on both shared internal and external ports.

1776-Drive Array Reports Improper SCSI Port 1 Cabling

1777-Slot X Drive Array - ProLiant Drive Storage Enclosure Problem Detected...

1778-Drive Array Resuming Automatic Data Recovery Process

1779-Slot X Drive Array - Replacement drive(s) detected OR previously failed drive(s) now operational:...

1783-Slot X Drive Array Controller Failure

1784-Slot X Drive Array Drive Failure. The Following SCSI Drive(s) Should Be Replaced: SCSI Port Y: SCSI ID Z

1785-Slot X Drive Array Not Configured...

1786-Disk 0 Software RAID Failure, Booting Disk 1

1786-Slot 1 Drive Array Recovery Needed...

1786-Slot 1 Drive Array Recovery Needed. Automatic Data Recovery Previously Aborted!...

1787-Drive Array Operating in Interim Recovery Mode...

1788-Slot X Drive Array Reports Incorrect Drive Replacement...

1789-Slot X Drive Array SCSI Drive(s) Not Responding...

1792-Drive Array Reports Valid Data Found in Array Accelerator...

1793-Drive Array - Array Accelerator Battery Depleted - Data Lost. (Error message 1794 also displays.)

1794-Drive Array - Array Accelerator Battery Charge Low...

1795-Drive Array - Array Accelerator Configuration Error...

1796-Drive Array - Array Accelerator Not Responding...

1797-Drive Array - Array Accelerator Read Error Occurred...

1798-Drive Array - Array Accelerator Self-Test Error Occurred...

1799-Drive Array - Drive(s) Disabled Due to Array Accelerator Data Loss...