1777-Slot X Drive Array - ProLiant Drive
Storage Enclosure Problem Detected...
(followed by one or more of
the following):
...SCSI Port Y: Cooling
Fan Malfunction Detected
SCSI Port Y: Overheated
Condition Detected
SCSI Port Y: Side-Panel
must be Closed to Prevent Overheating
SCSI Port Y: Redundant
Power Supply Malfunction Detected
SCSI Port Y: Wide SCSI
Transfer Failed
SCSI Port Y: Interrupt
Signal Inoperative
SCSI Port y: Unsupported
ProLiant Storage System Detected
Audible
Beeps: None
Possible
Cause: Environment threshold was violated on the drive
enclosure.
Action:
Check cooling fan operation by placing a
hand over the fan.
Be sure the internal plenum cooling fan in
tower servers or storage systems is operational. If the fan is not
operating, check for obstructions and check all internal
connections.
Replace unit side panel if removed.
Check the LEDs. If the ProLiant Storage
System power LED is amber instead of green, this indicates a
redundant power supply failure.
If the message indicates to check SCSI
cables:
Compare the cabling against the diagrams in
the HP Smart Array Controller User
Guide.
If the routing is correct, replace cables
on the specified port until the POST error message is
eliminated.