Enter the name of the SRT to create
|
The name of the SRT also is used for the directory that contains
it.
Only alphanumeric characters and the underscore (_) character
are allowed.
|
Enter the description of the new SRT
|
A description of the SRT.
|
SRT OS level
|
The levels you can create based on the operating system version
of the boot server.
|
Enter desired Architecture(32/64)
|
Enter whether 32-bit or 64-bit AIX operating system needs to be
installed into SRT.
Note:
|
This SRT operating system architecture type
is not related to the client operating system architecture type.
Instead, it is related to NetBackup client software going to be
installed into SRT.
In case you want to install NetBackup client of the versions
older than 7.0, into SRT, this OS architecture type should to be
selected as 32 bit. For NetBackup 7.0, select 64-bit as OS
architecture type.
During the "NetBackup client installation into SRT" step,
bmrsrtadm gives the appropriate error
message if there is any incompatibility between SRT OS architecture
type and NetBackup client version.
|
|
Enter the directory in which to place the new SRT
|
The path to the directory in which to create the SRT. The root
of the SRT (called the SRT path) is the path name to the SRT
location, which includes the SRT name.
The default is either /export/srt or the directory where an SRT
was last created successfully.
The directory must exist.
|
Location (device or directory path) of the Ignite install
media.
|
BMR searches for the following directory
(x.x is either 11.00 or 11.11):
If the BOSdatapath directory is found, BMR expects
the Ignite installation image to be in one of the following
directories. (Note that -PA indicates Ignite version B41.)
-
Ignite-UX/BOOT-KERNEL/opt/ignite/data
-
Ignite-UX/BOOT-KERNEL/opt/ignite/boot
-
Ignite-UX/BOOT-KERNEL-PA/opt/ignite/data
-
Ignite-UX/BOOT-KERNEL-PA/opt/ignite/boot
If the BOSdatapath directory is not found, BMR
looks for a file named INSTCMDS from the tar file supplied in one
the following directories: (Note that -PA indicates Ignite version
B41.)
If the file is not found, BMR cannot install Ignite.
|
Enter the location (device or directory path) of the HP-UX
x.x install media
|
The variable x.x is the SRT operating
system version.
|
The following patches are required for this SRT: patch_list
They can be found on an HP support plus media, or they can be
downloaded from HP Web site.
Location (device or path) of the media that contains
patch_list:
|
If your version of Ignite requires a patch, you are prompted to
provide the path to the specific patch that the version
requires.
|
Location (device or path) of the Symantec NetBackup install
media
|
Enter the name of the device where the NetBackup client software
installation media is inserted or enter the path to the
installation image.
After you enter the device name or path, the NetBackup client
installation procedure installs the client software into the
SRT.
|
|
The following appears when the NetBackup client software
installation process begins:
Symantec installation script
Copyright 1993 - 2007 Symantec Corporation, All Rights
Reserved.
Installing NetBackup Client Software
Note:
|
To install NetBackup server software, insert
the appropriate NetBackup server CD.
|
|
Do you want to continue? [y,n] (y) y
|
Enter y.
|
Do you want to install the NetBackup client software for this
client? [y,n] (y)
|
Enter y.
|
Enter the name of the NetBackup server:
|
Enter any non-blank value; the server name is replaced at
restore time with the correct values for the BMR client being
restored.
|
Would you like to use servername as
the configured name of the NetBackup client? [y,n] (y)
|
Accept the default or enter any nonblank value. The client name
is replaced at restore time with the correct values for the BMR
client being restored.
|