The iLO 3 settings commands enable you to view or modify iLO 3 settings. iLO 3 settings are located at /map1/config1.
Targets
No targets
Properties
Property |
Access |
Description |
---|---|---|
|
Read/Write |
Enables or disables the iLO 3. Boolean values are accepted. |
|
Read/Write |
Sets session timeout in minutes. Valid values are 15, 30, 60, and 120. |
|
Read/Write |
Enables or disables Terminal Services Passthrough. Boolean values are accepted. |
|
Read/Write |
Enables or disables RBSU prompt during POST. Boolean values are accepted. |
|
Read/Write |
Enables or disables login requirement for accessing RBSU. Boolean values are accepted. |
|
Read/Write |
Enables or disables iLO 3 IP address display during POST. Boolean values are accepted. |
|
Read/Write |
Sets the Remote Console configuration. Valid values are enabled, disabled, or automatic. |
|
Read/Write |
Enables or disables telnet. |
|
Read/Write |
Sets the HTTP port value. |
|
Read/Write |
Sets the SSL port value. |
|
Read/Write |
Sets remote console port value. |
|
Read/Write |
Sets virtual media port value. |
|
Read/Write |
Sets Terminal Services port value. |
|
Read/Write |
Sets the SSH port value. |
|
Read/Write |
Enables or disables SSH. Boolean values are accepted. |
|
Read/Write |
Enables or disables CLP session through serial port. Boolean values are accepted. |
|
Read/Write |
Enables or disables authorization requirement for CLP session through serial port. Boolean values are accepted. |
|
Read/Write |
Sets the serial port speed for the CLP session. The valid values are 9600, 19200, 38400, 57600, and 115200. |
|
Read/Write |
Sets the minimum password length requirement. |
oemhp_authfailurelogging |
Read/Write |
Sets the logging criteria for failed authentications. |
|
Read/Write |
Enables or disables remote console acquire operations. |
|
Read/Write |
Enables or disables high performance mouse. |
oemhp_computer_lock |
Read/Write |
Enables or disables the Remote Console Computer Lock. |
oemhp_enforce_aes |
Read/Write |
Enable or disable enforcing AES/3DES encryption |
Examples
set
/map1/config1 oemhp_enable=yes oemhp_timeout=30
You can specify one or more properties in the command line. If multiple properties are given on the same command line, they must be separated by a space.
oemhp_computer_lock
command
examples:
set /map1/config1 oemhp_computer_lock = windows
set /map1/config1 oemhp_computer_lock = custom,l_gui,l
set /map1/config1 oemhp_computer_lock = disabled
For a complete list of oemhp_computer_lock
custom keys, see
the HP Integrated Lights-Out 2 User Guide.
Any keys with a space must have the space replaced with an
underscore. For example:
set /map1/config1 oemhp_computer_lock = custom,SYS_RQ
set /map1/config1 oemhp_computer_lock = custom,SYS_RQ