The fault LED is illuminated on a parallel SCSI hard drive managed by an HP Smart Array controller
Action:
If the drive fault LED is illuminated, see the drive LED combination tables in "
Hard drive LED combinations
."
If the drive fault LED is flashing, replace the hard drive. See the server maintenance and service guide.
If the drive fault LED is not flashing and the operating system supports
HP Insight Diagnostics, version 7.40 or later
, perform the following:
Run the
Smart Array SCSI Diagnosis feature
.
Perform the actions recommended by the diagnosis report.
If the issue is still present, run ADU, version 7.31 or later.
For ADU report analysis, contact
HP support
.
If the drive fault LED is not flashing and the operating system does not support
HP Insight Diagnostics, version 7.40 or later
, insert the SmartStart CD and run ADU, version 7.31 or later. For ADU report analysis, contact
HP support
.