NetBackup status code: 302

Message: error encountered trying backup of catalog (multiple tape catalog backup)

Explanation: This error occurs when the NetBackup command that was used for stage one of the two-stage catalog backup fails.

Recommended Action: For the actual error that caused the failure, review the Vault debug log in the following directory:

	UNIX and Linux: /usr/openv/netbackup/logs/vault
	Windows: install_path\NetBackup\logs\vault

Review the summary.log in each of the sidxxx directories that had problems:

	UNIX and Linux: 
	/usr/openv/netbackup/vault/sessions/vault_name/sidxxx
	Windows: 
	install_path\NetBackup\vault\sessions\vault_name\sidxxx

(where xxx is the session ID)

In addition, review the admin debug log in the following directory:

	UNIX and Linux: /usr/openv/netbackup/logs/admin
	Windows: install_path\NetBackup\logs\admin

Correct the error and rerun the Vault session.