Changed parameter values for the inactive files reports and the largest files report

Note:

This section applies if you upgrade from any version of Enterprise Vault before Enterprise Vault 8.0 SP3.

From Enterprise Vault 8.0 SP3 onwards the default values of the data collection parameters for some reports were changed, to improve data scan performance. Table: Changes to the FSA Reporting data collection parameters describes the changes.

Table: Changes to the FSA Reporting data collection parameters

Parameter

Description

Supplied value before Enterprise Vault 8.0 SP3 (units)

Supplied value from Enterprise Vault 8.0 SP3 onwards (units)

DAYSOLD

Sets the data collection periods for the three "Inactive Files" reports

30,60,90,180,365,730,1095 (days)

90,180,365,730 (days)

MBLARGE

Sets the minimum file size for the "Largest files per Volume" report.

10 (MB)

1024 (MB)

TopFiles

Sets the number of files to list in the "Largest Files per Volume" report.

100 (files)

10 (files)

On upgrade to Enterprise Vault 9.0:

You can change the values of these parameters in the Enterprise Vault Directory database.

See "Modifying the FSA Reporting data collection parameters" in the Reporting guide.