Previous Topic

Next Topic

Hot-plug SAS hard drive LED combinations

Online/activity LED (green)

Fault/UID LED (amber/blue)

Interpretation

On, off, or flashing

Alternating amber and blue

The drive has failed, or a predictive failure alert has been received for this drive; it also has been selected by a management application.

On, off, or flashing

Steadily blue

The drive is operating normally, and it has been selected by a management application.

On

Amber, flashing regularly (1 Hz)

A predictive failure alert has been received for this drive.

Replace the drive as soon as possible.

On

Off

The drive is online, but it is not active currently.

Flashing regularly (1 Hz)

Amber, flashing regularly (1 Hz)

Do not remove the drive. Removing a drive may terminate the current operation and cause data loss.

The drive is part of an array that is undergoing capacity expansion or stripe migration, but a predictive failure alert has been received for this drive. To minimize the risk of data loss, do not replace the drive until the expansion or migration is complete.

Flashing regularly (1 Hz)

Off

Do not remove the drive. Removing a drive may terminate the current operation and cause data loss.

The drive is rebuilding, or it is part of an array that is undergoing capacity expansion or stripe migration.

Flashing irregularly

Amber, flashing regularly (1 Hz)

The drive is active, but a predictive failure alert has been received for this drive. Replace the drive as soon as possible.

Flashing irregularly

Off

The drive is active, and it is operating normally.

Off

Steadily amber

A critical fault condition has been identified for this drive, and the controller has placed it offline. Replace the drive as soon as possible.

Off

Amber, flashing regularly (1 Hz)

A predictive failure alert has been received for this drive. Replace the drive as soon as possible.

Off

Off

The drive is offline, a spare, or not configured as part of an array.

500 Internal Server Error

Internal Server Error

The server encountered an internal error or misconfiguration and was unable to complete your request.

Please contact the server administrator at webmaster@systemmanager.forsenergy.ru to inform them of the time this error occurred, and the actions you performed just before this error.

More information about this error may be available in the server error log.

Additionally, a 500 Internal Server Error error was encountered while trying to use an ErrorDocument to handle the request.