Power converter module

To remove the component:

  1. Power down the server.
  2. Extend or remove the server from the rack (Extend the server from the rack, Remove the server from the rack).
  3. Remove the access panel.
  4. Remove the front fan bracket.

    IMPORTANT: For this procedure, you do not need to remove the hot-plug fans from the front fan bracket. When reinstalling the front fan bracket, press the top of each fan to be sure it seats securely.

  5. Remove all hot-plug power supplies.
  6. Disconnect all power cables.

    Disconnecting the power cables from the system board

  7. Remove the power converter module.

    NOTE: Cables are removed for clarity.

    Removing the power converter module

To replace the component, reverse the removal procedure.

NOTE: The replacement (spare) power converter module may have an 8-pin connector. This connector will plug into the 6-pin header on models which support SCSI drives.