This function registers a network adapter-driver-supplied MiniportShutdownfunction to be called when the system is shutting down.

VOID NdisMRegisterAdapterShutdownHandler(
IN NDIS_HANDLE
MiniportHandle
,
IN PVOID
ShutdownContext
,
IN ADAPTER_SHUTDOWN_HANDLER
ShutdownHandler
);

Parameters

MiniportHandle
Specifies the handle input to the MiniportInitializefunction.
ShutdownContext
Pointer to a driver-determined context area. This pointer is passed to the function at ShutdownHandlerwhen it is called.
ShutdownHandler
Specifies the entry point of the caller's MiniportShutdownfunction.

Requirements

Runs on Versions Defined in Include Link to
Windows CE OS 2.0 and later Ndis.h   Ndislib.lib
Note   This API is part of the complete Windows CE OS package as provided by Microsoft. The functionality of a particular platform is determined by the original equipment manufacturer (OEM) and some devices may not support this API.

See Also

MiniportInitialize