Explanation: One or more command parameters were not valid. This error can occur when incompatible levels of NetBackup are installed on a master and its media server(s) or client(s). For example, a NetBackup master server has NetBackup 7.0 and the media server or the client has NetBackup 6.0.
This error can also occur if the wrong parameters are used when you run a command line.
Recommended Action: Do the following, as appropriate:
If the error occurs when you run a command on the command line, verify that the parameters are valid.
This status code may occur if nbjm passes parameters but does not have a required parameter. Check the nbjm unified logs (originator ID 117) for the list of parameters that were passed.
The following information pertains to NetBackup Snapshot Client.
If the following appears in the /usr/openv/netbackup/logs/bptm log as enabled on a third-party copy backup, multiplexing was enabled on a third-party copy backup.:
bptm: cannot perform Third-Party-Copy for multiplexed backups send_brm_msg: ERROR 20
The Third-Party Copy Device off-host backup method is incompatible with multiplexing (the writing of two or more concurrent backup jobs to the same storage device). You must disable multiplexing for any third-party copy backups. If multiplexing is enabled, the backup fails.
The media server may not have the correct 3pc. file entry for the client disk that is needed for the backup.
The following appears in the /usr/openv/netbackup/logs/bpbkar log:
14:45:00.983 [15773] <4> bpmap_mm_get_devid: GET_DEVICE_INDEX 1 EMC:SYMMETRIX:601092014000 14:45:00.986 [15773] <4> bpbkar child_send_keepalives: keepalive child started, pid = 15822 14:47:02.029 [15773] <4> bpmap_mm_get_devid: keepalive child: 15822 killed 14:47:02.030 [15773] <4> bpmap_mm_get_devid: DEVICE_INDEX -1 14:47:02.031 [15773] <16> bpmap_send_extend: ERR - can't obtain device id string EMC:SYMMETRIX:601092014000 14:47:33.167 [15773] <16> bpbkar Exit: ERR - bpbkar FATAL exit status = 227: no entity was found 14:47:33.167 [15773] <4> bpbkar Exit: INF - EXIT STATUS 227: no entity was found 14:47:33.168 [15773] <2> bpbkar Exit: INF - Close of stdout complete
This shows that a particular device cannot be found in the 3pc. file on the media server (14:47:02.031 [15773] <16> bpmap_send_extend: ERR - can't obtain device id string EMC:SYMMETRIX:601092014000).
The problem is one of the following:
The 3pc. file on the media server is outdated. Recreate the 3pc. file.
The media server is not on the same Fibre Channel network as the third-party copy device and client disk. As a result, the 3pc. file does not have a correct entry for the client disk. Run the bptpcinfo command with the -x client_name option; this option adds the client disk to the 3pc. file. For each disk that is added to the file by means of bptpcinfo -x client_name, you may need to add the device's worldwide name (wwn=).
See the NetBackup Snapshot Client Configuration online document.
See "Snapshot Client Assistance" in the NetBackup Snapshot Client Administrator's Guide.
The HP VxFS snapshot mechanism requires a dedicated cache partition for each snapshot. A check is made in the mount table to make sure that the cache partition is not already in use. If the cache partition is already in use, status code 20 occurs.
Check the /usr/openv/netbackup/logs/bpbkar log for a message similar to the following:
bpfsmap: FTL - bpfsmap: snapshot cache already in use, /dev/arrayvg/vol4c bpbkar Exit: ERR - bpbkar FATAL exit status = 20: invalid command parameter bpbkar Exit: INF - EXIT STATUS 20: invalid command parameter
If the snapshot cache partition is already in use, do one of the following: Set up your policy schedules to run at different times or use different cache partitions for each backup.
If the Allow multiple data streams option is enabled, each stream must have its own dedicated cache partition.
Compare the NetBackup version level on the server to the version level on the clients by doing the following:
On UNIX or Linux NetBackup servers and clients, check the /usr/openv/netbackup/bin/version file.
On Windows NetBackup servers, check the install_path\Netbackup\version.txt file or the About NetBackup item on the Help menu.
On Microsoft Windows clients, check the About NetBackup item on the Help menu.
On NetWare target clients, check the Version entry in the bp.ini file.
On Macintosh clients, check the version file in the bin folder in the NetBackup folder in the Preferences folder.
If a Java interface displays the error, tell them how to enable the debug print manager in the Java startup file. Retry and compare the parameters that were logged on the Java log with the parameters listed in the commands usage statement.
If these actions do not reveal the problem, do the following: Create a debug log directory for the process that returned this status code (if the process uses legacy logging). Then retry the operation and check the resulting log.