Example 1: Removing a volume from a robot

The following is an example of how to remove a volume from a robotic library. It does not matter whether the robot supports bar codes.

The following are the attributes for media ID 800001:

media ID

800001

media type

8MM cartridge tape

bar code

TL800001

media description

tl8 backup volume

volume pool

NetBackup

robot type

TL8 - Tape Library 8MM

volume group

EXB220

max mounts allowed

0 (unlimited)

Assume that you remove the volume from the robotic library, specify the following on the Media Settings tab, then run the update:

media type

DEFAULT

volume group

NONROB_8MM

volume pool

DEFAULT

The resulting volume attributes for media ID 800001 are as follows:

media ID

800001

media type

8MM cartridge tape

bar code

TL800001

media description

tl8 backup volume

volume pool

NetBackup

robot type

NONE - Not Robotic

volume group

NONROB_8MM

max mounts allowed

0 (unlimited)

The new residence information in the EMM database shows a stand-alone location in the volume group. The volume group is specified on the Media Settings tab. The media type and volume pool remain unchanged.

The results are the same for a volume that does not have a bar code.