Configuration steps

Perform the steps described in this section to configure access for OWA basic authentication users.

To enable OWA basic access to archived items

  1. Log on to the ISA Server 2004 computer as a local administrator with permissions to configure the ISA Server.

  2. Open the Microsoft Internet Security and Acceleration Server 2004 management console and expand the server name.

  3. Click the Firewall Policy node.

  4. In the right-hand task pane, click the Tasks tab and then click Publish a Mail Server.

  5. On the Welcome to the New Mail Server Publishing Rule Wizard page, enter a name for the rule in the Mail Server Publishing Rule name box. For example, OWA Basic (External to Internal). Click Next.

  6. On the Select Access Type page, select Web client access: Outlook Web Access (OWA), Outlook Mobile Access, Exchange Server ActiveSync. Click Next.

  7. On the Select Services page, select Outlook Web Access and click Next.

  8. On the Bridging Mode page, select Secure connection to clients and mail server, and click Next.

  9. On the Specify the Web Mail Server page, enter the name of the front-end Exchange server (as identified to the internal network) in the Web mail server box.

    Alternatively, you can enter the common name of the CA certificate on the front-end Exchange server. This is the Issued to name in the certificate.

    Click Next.

  10. On the Public Name Details page, enter the name that external users will use to access the OWA site in the Public name box. This must match what is specified in the external DNS entry.

    Alternatively, select Accept requests for any domain name in the drop-down box. Click Next.

  11. On the Select Web Listener page, click New to create a new Web listener. (This step assumes that no Web listener exists yet.)

  12. On the Welcome to the New Web Listener Wizard page, enter a name for the listener in the Web listener name box. For example, External443. Click Next.

  13. On the IP Addresses page, select the External check box. Click Next.

  14. On the Port Specification page, clear the Enable HTTP check box, and then perform the following steps in the order listed:

    • Select Enable SSL.

    • Click Select. In the Select Certificate dialog box, click the Web site certificate (front-end Exchange server), and click OK.

    • Click Next on the Port Specification page.

  15. Click Finish on the Completing the New Web Listener Wizard page.

  16. Click Edit on the Select Web Listener page, and then perform the following steps in the order listed:

    • Select the Preferences tab. In the Web Listener dialog box, click Authentication.

    • In the Authentication dialog box, clear the Integrated check box.

    • Click OK in the prompt dialog.

    • Select the Basic check box.

    • Click Yes in the dialog box informing you that you should use SSL.

    • Click OK in the Authentication dialog box.

  17. Click Apply and then click OK in the Web Listener dialog box.

  18. Click Next on the Select Web Listener page.

  19. On the User Sets page, accept the default setting, All Users, and click Next.

  20. Click Finish on the Completing the New Mail Server Publishing Rule Wizard page.

  21. Right-click the newly created rule in the main Firewall Policy pane of the Microsoft Internet Security and Acceleration Server 2004 management console, and click Properties.

  22. In the Properties dialog box, click the Paths tab, and then perform the following steps in the order listed:.

    • Click Add.

    • In the Path mapping dialog box, enter the value /EnterpriseVaultProxy/* in the box Specify the folder on the Web site that you want to publish. (If you want to publish the entire Web site, leave this box blank.)

    • Select Same as published folder.

    • Click OK.

  23. Click Apply and then click OK in the Properties dialog box.

  24. Click Apply to save the changes and update the firewall policy.

  25. Click OK in the Apply New Configuration dialog box.

500 Internal Server Error

Internal Server Error

The server encountered an internal error or misconfiguration and was unable to complete your request.

Please contact the server administrator at webmaster@systemmanager.forsenergy.ru to inform them of the time this error occurred, and the actions you performed just before this error.

More information about this error may be available in the server error log.

Additionally, a 500 Internal Server Error error was encountered while trying to use an ErrorDocument to handle the request.