The sample script in this section gives all possible values for each option.
You can use this script as a template for your own script. The Control category has the following options:
Action =
Configure|Reconfigure
Method =
Custom|
Auto ; COMMENT:
ACU cannot create a RAID 50 or RAID 60 configuration in Auto mode.
You must create such configurations manually using the Custom
setting.
Controller = All | First | Slot [
N][:
N] | WWN
[
N] | SerialNumber [
N] | IOCabinet
[
N],IOBay [
N],IOChassis
[
N],Slot [
N],Cabinet
[
N],Cell [
N]
ClearConfigurationWithDataLoss =
Yes|
No ; COMMENT: This
option is now deprecated.
LicenseKey =
XXXXX-XXXXX-XXXXX-XXXXX-XXXXX
DeleteLicenseKey =
XXXXX-XXXXX-XXXXX-XXXXX-XXXXX | * ; COMMENT: * is a wild card that
enables you to delete all license keys on the specified
controller.
RAIDArrayID = "XXXXXXXXXXXXXXXXXXXX"
ReadCache =
0|10|20|25|30|40|
50|60|70|75|80|90|100
WriteCache =
0|10|20|25|30|40|
50|60|70|75|80|90|100
RebuildPriority =
Low|Medium|High
ExpandPriority =
Low|Medium|High
SurfaceScanDelay =
N
SSPState = Enable|
Disable
PreferredPathMode = Auto|Manual
; COMMENT: the following five entries are used to optimize the controller performance for video
MNPDelay = 0|1|2|...|60 ; units are minutes, zero indicates disabled
IRPEnable = Yes|No
DPOEnable = Yes|No
ElevatorSortEnable = Yes|No
QueueDepth = 2|4|8|16|32|Auto
Array =
A|B|C|D|E|F|G|...Z|a|b|c|d|e|f
OnlineSpare =
None |
N
| Port:ID,Port:ID... |
Box:Bay,Box:Bay... | Port:Box:Bay,Port:Box:Bay,... ; COMMENT: These
values are available only in Custom method mode. In Auto method
mode, the choices are
Yes|No.
Drive = * |
N
| Port:ID,Port:ID... |
Box:Bay,Box:Bay... | Port:Box:Bay,Port:Box:Bay,...
DriveType = SCSI | SAS | SATA
LogicalDrive = 1|2|3|...32
RAID
= 0|1|5|50|6|60|adg|
auto ;
COMMENT: RAID 6 and 60 are only available when SAAP is installed
and the license key registered
ParityGroups =
2|
N
; COMMENT: Necessary only for RAID
50 or 60.
N > 2
Size
= [
N]|
Max
Sectors =
32|63
StripeSize = 8|16|32|64|128|256
ArrayAccelerator =
Enable|Disable
LogicalDriveSSPState =
Enable|
Disable
SSPAdaptersWithAccess = [
N],[
N]...|None
PreferredPath =
1|2
HBA_WW_ID = WWN
ConnectionName = UserDefinedName
HostMode = Default | Windows | Windows(degrade
| openVMS | Tru64 | Linux | Solaris | Netware | HP | Windows Sp2 ;
COMMENT: The Windows(degrade value must be entered as
written.