The sample script in this section gives all possible values for each option.
You can use this script as a template for your own script. The Control category has the following options:
Action =
Configure|Reconfigure
Method
Auto ;
COMMENT: ACU cannot create a RAID 50 or RAID 60 configuration in
Auto mode. You must create such configurations manually using the
Custom setting.=
Custom|
Controller
N= All | First
| Slot [
N][:
N] | WWN [
N] | SerialNumber [
N] | IOCabinet [
N],IOBay [
N],IOChassis [
N],Slot [
N],Cabinet [
N],Cell [
]
No ;
COMMENT: This option is now deprecated.ClearConfigurationWithDataLoss =
Yes|
LicenseKey =
XXXXX-XXXXX-XXXXX-XXXXX-XXXXX
DeleteLicenseKey =
XXXXX-XXXXX-XXXXX-XXXXX-XXXXX | * ; COMMENT: * is a wild card that
enables you to delete all license keys on the specified
controller.
RAIDArrayID =
"XXXXXXXXXXXXXXXXXXXX"
50ReadCache =
0|10|20|25|30|40|
|60|70|75|80|90|100
50WriteCache =
0|10|20|25|30|40|
|60|70|75|80|90|100
Low|RebuildPriority =
Medium|High
LowExpandPriority =
|Medium|High
NSurfaceScanDelay =
Disable
SSPState =
Enable|
PreferredPathMode = Auto|Manual
; COMMENT: the following five entries are used to optimize the controller performance for video
MNPDelay = 0|1|2|...|60 ; units are minutes, zero indicates disabled
IRPEnable = Yes|No
DPOEnable = Yes|No
ElevatorSortEnable = Yes|No
QueueDepth = 2|4|8|16|32|Auto
Array =
A|B|C|D|E|F|G|...Z|a|b|c|d|e|f
None
OnlineSpare
=
N
|
Yes|
Port:ID,Port:ID... | Box:Bay,Box:Bay... |
Port:Box:Bay,Port:Box:Bay,... ; COMMENT: These values are available
only in Custom method mode. In Auto method mode, the choices
are
|No.
N Drive = *
|
|
Port:ID,Port:ID... | Box:Bay,Box:Bay... |
Port:Box:Bay,Port:Box:Bay,...
DriveType =
SCSI | SAS | SATA
LogicalDrive =
1|2|3|...32
auto RAID =
0|1|5|50|6|60|adg|
; COMMENT:
RAID 6 and 60 are only available when SAAP is installed and the
license key registered
2ParityGroups
=
N
|
N ;
COMMENT: Necessary only for RAID 50 or 60.
> 2
NSize =
[
Max
]|
32Sectors
=
|63
StripeSize =
8|16|32|64|128|256
EnableArrayAccelerator =
|Disable
Disable
LogicalDriveSSPState =
Enable|
NSSPAdaptersWithAccess =
[
N],[
]...|None
1PreferredPath
=
|2
HBA_WW_ID = WWN
ConnectionName = UserDefinedName
HostMode =
Default | Windows | Windows(degrade | openVMS | Tru64 | Linux |
Solaris | Netware | HP | Windows Sp2 ; COMMENT: The Windows(degrade
value must be entered as written.